Please log in to use the advanced features for product identification.
Credit line exceeded
Orders on hold
No results were found for the filter!
KNORR-BREM
K058032N00 K058032N00 Directional Control Valve Block, air suspension KNORR BREMSE ELC VALVE BLOCK

Technical Information:
Product family description: ELC
Air Inlet port(s) size:
Raufoss ABC KARTRIDGE REGULAR 12x1.5
Air Delivery port(s) size:
Raufoss ABC KARTRIDGE SMALL 8x1
Air Signal port(s) size:
Raufoss ABC KARTRIDGE REGULAR 12x1.5
Exhaust Connector: Exhaust Silencer fitted
Electrical Connection: ISO 15170-A1-2.1-SnK1
Voltage [volts]: 24
Kneeling function: Yes
Cross throttling feature: Yes
KNORR-BREM
II15587000 II15587000 Multi-circuit Protection Valve FOUR CIRCUIT PROT. VALVE

Technical Information:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: M16X1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,0-0,3 / >4,7
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,0-0,3 / >4,7
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Non-feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
5,7-0,3 / >4,7
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Non-feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
5,7-0,3 / >4,7
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Not included
Circuits' supply:
Internal series supply from Circuits 1 and 2 to 3 and 4
With Electrical pressure sensing: No
KNORR-BREM
II40246F II40246F Multi-circuit Protection Valve FOUR CIRCUIT PROT. VALVE

Technical Information:
Air Inlet port(s) size: M22x1,5
Air Delivery port(s) size: 21,22,23,24: M16x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
8,0-0,3/ >=5,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
8,0-0,3/ >=5,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
8,3+0,2/ >=5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
8,1+0,2/ >=5,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal parallel supply to 2
With Electrical pressure sensing: No
KNORR-BREM
K000500 K000500 Multi-circuit Protection Valve FOUR CIRCUIT PROT. VALVE

Technical Information:
Air Inlet port(s) size: Voss NG12 M22x1,5
Air Delivery port(s) size:
21,22,23,24: Voss NG12 M22x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
7,1-0,3/ >=5,5
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
7,1-0,3/ >=5,5
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,1-0,3/ >=5,5
Circuit 3 - Pressure Limiting [bar]: Not included
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,1-0,3/ >=5,5
Circuit 4 - Pressure Limiting [bar]: Not included
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: No
KNORR-BREM
K002435N50 K002435N50 Multi-circuit Protection Valve FOUR CIRCUIT PROT. VALVE

Technical Information:
Air Inlet port(s) size: Flange
Air Delivery port(s) size:
21,22,23,24,25,26: Voss NG12 M22X1,5; 27,28:M12x1,5
Circuit 1: Feedback with Bypass
Circuit 1 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 1 - Pressure Limiting [bar]: Not included
Circuit 2: Feedback with Bypass
Circuit 2 - Open/close pressure [bar]:
9,0-0,3 / >=6,0
Circuit 2 - Pressure Limiting [bar]: Not included
Circuit 3: Feedback with no Bypass
Circuit 3 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 3 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Circuit 4: Feedback with no Bypass
Circuit 4 - Open/close pressure [bar]:
7,5-0,3 / >=4,5
Circuit 4 - Pressure Limiting [bar]: 8,5 +0,0/-0,4
Bleed-back safety feature:
Controlled by Circuit 1
Circuits' supply: Internal series supply from 1
With Electrical pressure sensing: Yes
56 From 71
Viewed